What was found
TUL - CORROSION 1 INCH BELOW FLOORBOARD, STA 1177, LBL 12 INCHES TO 16 INCHES, IN AFT CARGO. REMOVED FLOOR WEB AND INSTALLED NEW FLOOR WEB PER SRM 51-30-2, SRM 51-20-4. TST: 42,325 HRS. CYCLES, 22,016. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - CORROSION 1 INCH BELOW FLOORBOARD, STA 1177, LBL 12 INCHES TO 16 INCHES, IN AFT CARGO. REMOVED FLOOR WEB AND INSTALLED NEW FLOOR WEB PER SRM 51-30-2, SRM 51-20-4. TST: 42,325 HRS. CYCLES, 22,016. (X)