What was found
TUL - FOUND STRINGER CAPS 45, 46 AND 47 HAVE CORROSION UNDERNEATH AT STATION 1139 TO 1159. REMOVED CORROSION PER 53-20-00. CUT OUT CORROSION AREA INSTALLED REPAIR PER SRM 53-20-00 FIG 6. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND STRINGER CAPS 45, 46 AND 47 HAVE CORROSION UNDERNEATH AT STATION 1139 TO 1159. REMOVED CORROSION PER 53-20-00. CUT OUT CORROSION AREA INSTALLED REPAIR PER SRM 53-20-00 FIG 6. (M)