What was found
TUL - FOUND CORROSION ON TOP OF TRACK NR 1 AND GALLEY TIE DOWNS HAS INTERGRANULAR CORROSION IS FROM STATION 1212-1250. CUT OUT AREA THAT WAS BEYOND LIMITS AND INSTALLED PLUG PER SRM 53-05 FIG 4A AND TREATED AND PRIMED. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND CORROSION ON TOP OF TRACK NR 1 AND GALLEY TIE DOWNS HAS INTERGRANULAR CORROSION IS FROM STATION 1212-1250. CUT OUT AREA THAT WAS BEYOND LIMITS AND INSTALLED PLUG PER SRM 53-05 FIG 4A AND TREATED AND PRIMED. (M)