What was found
AFW - FOUND TWO GOUGES ON SKIN LAP AFT APPROX 7 INCHES OF L-2 DOOR. FOUND BEYOND SRM LIMITS AFTER BLENDING. EDDY CURRENT CHECKED. NO CRACKS FOUND. COUNTERSINKED AND REPLACED FASTENERS. APPROVED BY ENGINEERING PER MRB 767-1219. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFW - FOUND TWO GOUGES ON SKIN LAP AFT APPROX 7 INCHES OF L-2 DOOR. FOUND BEYOND SRM LIMITS AFTER BLENDING. EDDY CURRENT CHECKED. NO CRACKS FOUND. COUNTERSINKED AND REPLACED FASTENERS. APPROVED BY ENGINEERING PER MRB 767-1219. (M)