What was found
AFW - FOUND FLOOR BEAM AT STATION 345 HAS CORROSION REMOVED ON UPPER SURFACE. MATERIAL REMAINING IS BEYOND SRM LIMITS, PER MRB 757-836. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFW - FOUND FLOOR BEAM AT STATION 345 HAS CORROSION REMOVED ON UPPER SURFACE. MATERIAL REMAINING IS BEYOND SRM LIMITS, PER MRB 757-836. (M)