What was found
AFW - FOUND CORROSION ON FLOOR BEAM AFTER BLENDING TO BE BEYOND SRM LIMITS. FOUND AND BLENDED OUT CORROSION. ATTACHED A FABRICATED STRAP OF .050 301 1/2 HARD STAINLESS. ALODINED, PRIMED AND PAINTED PER ENGINEERING MRB NR 767-1237. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFW - FOUND CORROSION ON FLOOR BEAM AFTER BLENDING TO BE BEYOND SRM LIMITS. FOUND AND BLENDED OUT CORROSION. ATTACHED A FABRICATED STRAP OF .050 301 1/2 HARD STAINLESS. ALODINED, PRIMED AND PAINTED PER ENGINEERING MRB NR 767-1237. (M)