What was found
AFW - FOUND FLOOR BEAM, AT STATION 365, HAS CORROSION REMOVED ON UPPER SURFACE, MATERIAL REMAINING IS BEYOND SRM LIMITS. PER MRB 757-845. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFW - FOUND FLOOR BEAM, AT STATION 365, HAS CORROSION REMOVED ON UPPER SURFACE, MATERIAL REMAINING IS BEYOND SRM LIMITS. PER MRB 757-845. (M)