What was found
MIA - DURING OVERNIGHT MAINTENANCE, FOUND THE FIRST CLASS EMERGENCY EXIT FLOOR PATH LIGHTS INOPERATIVE. SECURED FIRST CLASS EMERGENCY EXIT FLOOR PATH LIGHT STRIP. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MIA - DURING OVERNIGHT MAINTENANCE, FOUND THE FIRST CLASS EMERGENCY EXIT FLOOR PATH LIGHTS INOPERATIVE. SECURED FIRST CLASS EMERGENCY EXIT FLOOR PATH LIGHT STRIP. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)