What was found
AFW - FOUND AND BLENDED CORROSION IN 2 AREA OF THE UPPER SURFACE OF THE CABIN FLOOR BEAMS. THE BLENDOUTS EXCEEDED SRM ALLOWABLE LIMITS. CUT EACH FLOOR BEAM OF STATION 843.5 AND 876.8. SPLICED NEW SECTIONS OF FLOOR BEAM. ACCOMPLISHED PER APPROVED ENGINEERING INSTRUCTIONS OF MRB 767-1264. (M)