What was found
TUL - FOUND CORROSION AND BULGED SEALANT IN LEFT NLG TRUNNION TORQUE BOX WELL BILDGE AREA, STATION 300. CORROSION ON SKATE ANGLE IN NLG LEFT TORQUE BOX. REMOVED AND REPLACED LEFT SKATE ANGLE WITH NEW PART PER SRM 53-10-4. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND CORROSION AND BULGED SEALANT IN LEFT NLG TRUNNION TORQUE BOX WELL BILDGE AREA, STATION 300. CORROSION ON SKATE ANGLE IN NLG LEFT TORQUE BOX. REMOVED AND REPLACED LEFT SKATE ANGLE WITH NEW PART PER SRM 53-10-4. (M)