What was found
TUL - FOUND FUSELAGE SKIN CORRODED 2 INCHES BY 8 INCHES STATION 660, STRINGER 28R TO 27L. CORROSION AREA CUT OUT AND INSTALLED DOUBLER PER SRM 53-30-3 FIG 3. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND FUSELAGE SKIN CORRODED 2 INCHES BY 8 INCHES STATION 660, STRINGER 28R TO 27L. CORROSION AREA CUT OUT AND INSTALLED DOUBLER PER SRM 53-30-3 FIG 3. (M)