SDR AALA961770

Service difficulty report · Temp Sensor · Airbus A300B4605R

Difficulty date
December 7, 1996
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N14077
Make and model
Airbus A300B4605R
Aircraft serial
612
Part
Temp Sensor
Part number
6177862
Condition
Defective
Location
Right
Stage of operation
DE
Nature of condition
J
Precautionary procedure
B

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

MIA - FLT 1315 - DURING DESCENT INTO MIA AT APPROXIMATELY FL 250, RIGHT BLEED VALVE FAILED. CABIN PRESSURE STARTED TO CLIMB RAPIDLY. FLIGHT CREW DECLARED EMERGENCY, STARTED RAPID DESCENT AND RESET BOTH BLEED VALVES. BLEED VALVES WORKED FOR SHORT TIME. STARTED APU TO CONTROL CABIN PRESSURE. AIRCRAFT LANDED MIA WITHOUT FURTHER INCIDENT. REPLACED NR 2 ENGINE TEMPERATURE CONTROL SENSOR AND NR 1 PNEUMATIC CONTROLLER. ACCOMPLISHED HIGH POWER ENGINE RUN. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)