What was found
AFW - FLOOR BEAM AT STA 3877 HAS CORROSION REMOVAL ON UPPER SURFACE. MATERIAL REMAINING IS BEYOND SRM LIMITS. REPAIR PER MRB 757-1014. TST: 15,056.39 HOURS. CYCLES, 5,412. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFW - FLOOR BEAM AT STA 3877 HAS CORROSION REMOVAL ON UPPER SURFACE. MATERIAL REMAINING IS BEYOND SRM LIMITS. REPAIR PER MRB 757-1014. TST: 15,056.39 HOURS. CYCLES, 5,412. (X)