What was found
AFW - FOUND FLOORBEAM AT STATION 345 HAS GOUGE/CORROSION REMOVED ON UPPER SURFACE. MATERIAL REMAINING IS BEYOND SRM ALLOWABLE LIMITS. REPAIRED PER MRB 757-1024. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFW - FOUND FLOORBEAM AT STATION 345 HAS GOUGE/CORROSION REMOVED ON UPPER SURFACE. MATERIAL REMAINING IS BEYOND SRM ALLOWABLE LIMITS. REPAIRED PER MRB 757-1024. (M)