What was found
DFW - FLT 1528 - AFTER TAKEOFF MEX WHEN LANDING GEAR RETRACTED, NO RED NOSE LANDING GEAR INDICATION ON INSTRUMENT PANEL AS GEAR RETRACTED. ALL INDICATIONS ON F/E PANEL NORMAL. AIRCRAFT PROCEEDED TO DFW AND ALL LANDING GEAR INDICATIONS NORMAL WHEN GEAR EXTENDED. AIRCRAFT LANDED DFW WITHOUT INCIDENT. REPLACED NOSE LANDING GEAR LOCK AND POSITION WIRE HARNESS. ACCOMPLISHED LANDING GEAR RETRACTION CHECK WITH NO DEFECTS FOUND. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)