What was found
TUL - FOUND CORROSION INSIDE STRINGER 26R AT STATION 1148. REMOVED CORRODED SECTION OF STRINGER STATION 1148-1152 STRINGER 26R AND REPAIRED STRINGER PER SRM 53-10-3. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND CORROSION INSIDE STRINGER 26R AT STATION 1148. REMOVED CORRODED SECTION OF STRINGER STATION 1148-1152 STRINGER 26R AND REPAIRED STRINGER PER SRM 53-10-3. (M)