What was found
TUL - FOUND STRINGER 68 CRACKED APPROXIMITY 2 INCHES FORWARD OF FRAME STATION 4150. CRACK EXTENDS FROM RIVET HOLE PERPENDICULAR UP VERTICAL PORTION OF STRINGER. REPAIRED STRINGER PER SRM 51-70-06-R5. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND STRINGER 68 CRACKED APPROXIMITY 2 INCHES FORWARD OF FRAME STATION 4150. CRACK EXTENDS FROM RIVET HOLE PERPENDICULAR UP VERTICAL PORTION OF STRINGER. REPAIRED STRINGER PER SRM 51-70-06-R5. (M)