What was found
TUL - STRINGER 29 LEFT, OUTBOARD LEG OF STRINGER IS CORRODED AT STATION 950E PLUS 2 INCHES, AND 950 E PLUS 18 INCHES, AT FASTENERS EACH END BAY. REMOVED CORROSION, REMOVED ALL FASTENER STATION 950E TO 950F. INSTALLED STRAP 7075-T6 BY .063 THICK WET WITH SEALER. REINSTALLED 1ST O/S HI-LOKS. ALL FASTENER HOLES, SEALED AROUND EDGES. REF ESO 11697 DATED 2-26-97. (M)