What was found
TUL - STRINGER 24R END CORRODED FORWARD OF STATION 740 BULKHEAD. INSTALLED NEW PIECE OF STRINGER AND STRINGER SPLICE AS PER SRM 53-10-3. SEALED TREATED AND PRIMED AREA PER MM 51-20-0. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - STRINGER 24R END CORRODED FORWARD OF STATION 740 BULKHEAD. INSTALLED NEW PIECE OF STRINGER AND STRINGER SPLICE AS PER SRM 53-10-3. SEALED TREATED AND PRIMED AREA PER MM 51-20-0. (M)