What was found
TUL - BS 540, BELL FRAME CRACKED .50 INCH AT FASTENER HOLE BETWEEN STR 8 AND STR 9R. ROUTED OUT CRACK AND INSTALLED DOUBLER PER SRM 53-10-4 PAGE 4 FIGURE 1. TST: 76,923 HOURS. CYCLES: 52,656. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - BS 540, BELL FRAME CRACKED .50 INCH AT FASTENER HOLE BETWEEN STR 8 AND STR 9R. ROUTED OUT CRACK AND INSTALLED DOUBLER PER SRM 53-10-4 PAGE 4 FIGURE 1. TST: 76,923 HOURS. CYCLES: 52,656. (X)