What was found
AFW - FLOOR STRUCTURE AT STATION 332 RBL 3 HAD CORROSION BLENDED BEYOND SRM LIMITS E58 NR 1668880. REPAIRED PER MRB NR 757-1105. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFW - FLOOR STRUCTURE AT STATION 332 RBL 3 HAD CORROSION BLENDED BEYOND SRM LIMITS E58 NR 1668880. REPAIRED PER MRB NR 757-1105. (M)