What was found
AFW - FOUND CORROSION REMOVED FROM CABIN FLOORBEAM STATION 1640 BEYOND SRM LIMITS. BLENDED CORRODED AREAS, ALODINED, FABRICATED REPAIR STRAP FROM STAINLESS STEEL. PRIMED STRAP AND FLOORBEAM, FILLED BLEND AREA, INSTALLED REPAIR STRAP. (M)