What was found
AFW - FORWARD CABIN FLOORBEAM STATION 377 HAD CORROSION BLENDED BEYOND SRM LIMITS. BLENDED BOTH AREAS LBL 31 AND LBL 56, ALODINED AND PRIMED, FILLED BLENDS, SATISFACTORY FOR CONTINUED SERVICE PER MRB 757-1119. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFW - FORWARD CABIN FLOORBEAM STATION 377 HAD CORROSION BLENDED BEYOND SRM LIMITS. BLENDED BOTH AREAS LBL 31 AND LBL 56, ALODINED AND PRIMED, FILLED BLENDS, SATISFACTORY FOR CONTINUED SERVICE PER MRB 757-1119. (M)