What was found
AFW - AFT CABIN FLOORBEAM STATION 1640 HAD CORROSION BEYOND SRM LIMITS. ALODINED BLEND AREAS, FABRICATED REPAIR STRAP FROM STAINLESS STEEL. PRIMED, FILLED BLENDED AREAS, INSTALLED STRAPS WET WITH SEALANT. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFW - AFT CABIN FLOORBEAM STATION 1640 HAD CORROSION BEYOND SRM LIMITS. ALODINED BLEND AREAS, FABRICATED REPAIR STRAP FROM STAINLESS STEEL. PRIMED, FILLED BLENDED AREAS, INSTALLED STRAPS WET WITH SEALANT. (M)