What was found
TUL - FOUND STRINGER 19R BELOW AVIONICS OUTFLOW DUCT BADLY CORRODED. CUT OUT DAMAGED AREA OF STRINGER AND REPLACED WITH REPAIR SECTION PER SRM 53-10-3 PG 3-4B. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND STRINGER 19R BELOW AVIONICS OUTFLOW DUCT BADLY CORRODED. CUT OUT DAMAGED AREA OF STRINGER AND REPLACED WITH REPAIR SECTION PER SRM 53-10-3 PG 3-4B. (M)