What was found
MIA - FLT 931 - ON TAKEOFF LEFT BUS FAILED AND ISOLATED, UNABLE TO RESTORE ANY POWER ON LAC BUS. REPLACED LEFT ENGINE IDG PERFORMED BITE LOAD AND DISCONNECT CHECKS PER MM OPERATION NORMAL LEAKS CHECKS OK. AS PRECAUTIONARY, REF MM 24-51-08-4 P. 403 AND ACCOMPLISH A TEST OF THE INSTRUMENT BUS VOLTAGE SENSING UNIT. REPORT YOUR FINDINGS IN FMR. ACCOMPLISHED TFI, LEFT AND RIGHT INSTRUMENT BUSSES TRANSFER NORMALLY. PERFORMED BITE ON BPCU. NO FAULTS FOUND. (M)