What was found
TUL - DURING C-CHECK, FOUND CORROSION AT L3 DOOR INSIDE NR 7 DOOR STOP ATTACH HOLES IN AFT DOOR FRAME STA 1305 AND CORROSION INSIDE NR 4 AND NR 5 DOOR STOP ATTACH HOLES IN FWD DOOR FRAME STA 1256. REAMED HOLES TO REMOVE CORROSION, TREATED, PRIMED, SRM 51-21-01, VOL II, AND INSTALLED BUSHINGS PER ESO 7349 DATED 4-15-97. TST: 91,786.20 HOURS. CYCLES: 18,348. (X)