What was found
TUL - FLOOR BEAM CORRODED BL ZERO STA 1110. CUT OUT DAMAGED SECTION OF FLOOR BEAM AND INSTALLED REPAIR DOUBLER PER SRM 53-10-8. 77,504 HOURS. CYCLES, 52,602. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FLOOR BEAM CORRODED BL ZERO STA 1110. CUT OUT DAMAGED SECTION OF FLOOR BEAM AND INSTALLED REPAIR DOUBLER PER SRM 53-10-8. 77,504 HOURS. CYCLES, 52,602. (X)