What was found
TUL - CRACK AT RIVET IN BELL FRAME BS 930 ABOVE STR 13R. INSTALLED DOUBLER IN BELL FRAME BS 930 PER SRM 53-10-4. STOP DRILLED CRACK. 77,504 HOURS. CYCLES, 52,602. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - CRACK AT RIVET IN BELL FRAME BS 930 ABOVE STR 13R. INSTALLED DOUBLER IN BELL FRAME BS 930 PER SRM 53-10-4. STOP DRILLED CRACK. 77,504 HOURS. CYCLES, 52,602. (X)