What was found
TUL - 1.50 INCH CRACK FROM FASTENER HOLE TO CENTER OF LEFT 930 FRAME AT STR 14. STOP DRILLED CRACK AND INSTALLED REPAIR PER SB 727-53-0162, REV FEB 21, 1991. TST: 75,765. CYCLES: 52,034. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - 1.50 INCH CRACK FROM FASTENER HOLE TO CENTER OF LEFT 930 FRAME AT STR 14. STOP DRILLED CRACK AND INSTALLED REPAIR PER SB 727-53-0162, REV FEB 21, 1991. TST: 75,765. CYCLES: 52,034. (X)