TUL - .5 INCH BY .042 INCH DENT AT FS 360 BETWEEN STR 5 AND STR 6 RIGHT ABOVE AND AFT OF FORWARD ENTRY DOOR. INSTALLED PERMANENT REPAIR PER SRM 53-30-3, FIG 1. TST: 55,431 HOURS. CYCLES, 34,330. (X)