What was found
TUL - CORROSION AT DOME NUT INSIDE STR 28L AT STA 699. REMOVED CORROSION SRM 51-10-6. INSTALLED DOUBLER PER SRM 53-10-3, FIG 2, SHEET 3. TST: 69,103. CYCLES: 47,232. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - CORROSION AT DOME NUT INSIDE STR 28L AT STA 699. REMOVED CORROSION SRM 51-10-6. INSTALLED DOUBLER PER SRM 53-10-3, FIG 2, SHEET 3. TST: 69,103. CYCLES: 47,232. (X)