What was found
TUL - FOUND L 29 R HAS CORROSION AT DRAIN HOLE STATION 1289. CUT OUT SECTION OF LONGERON INSTALLED SPLICE SECTION PER SRM 53-02 FIG 1 FROM STATION 1275 TO STATION 1295 AT LONGERON 29R. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND L 29 R HAS CORROSION AT DRAIN HOLE STATION 1289. CUT OUT SECTION OF LONGERON INSTALLED SPLICE SECTION PER SRM 53-02 FIG 1 FROM STATION 1275 TO STATION 1295 AT LONGERON 29R. (M)