What was found
TUL - FORWARD ENTRY DOOR UPPER HINGE CUT-OUT CRACKED. VERIFIED WITH HFEC (MARKED) EXTERNAL. ROUTED OUT CRACK AND INSTALLED DOUBLER AND FILLERS IAW SB 727-53-0198, FIG 4. TST: 43,979 HOURS. CYCLES, 23,058. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FORWARD ENTRY DOOR UPPER HINGE CUT-OUT CRACKED. VERIFIED WITH HFEC (MARKED) EXTERNAL. ROUTED OUT CRACK AND INSTALLED DOUBLER AND FILLERS IAW SB 727-53-0198, FIG 4. TST: 43,979 HOURS. CYCLES, 23,058. (X)