What was found
TUL - FOUND STRINGER 30 CORRODED NEXT TO DRAIN MAST ATTACHMENT STATION 1155. REPAIRED STRINGER 30 WITH SPLICE REPAIR, SRM 53-10-3 FIG 1, PAGE 1-11. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND STRINGER 30 CORRODED NEXT TO DRAIN MAST ATTACHMENT STATION 1155. REPAIRED STRINGER 30 WITH SPLICE REPAIR, SRM 53-10-3 FIG 1, PAGE 1-11. (M)