What was found
AFW - FOUND AND BLENDED OUT CORROSION ON THE UPPER SURFACE OF THE MAIN CABIN FLOOR BEAM IN VARIOUS LOCATIONS. THE BLEND-OUTS EXCEED SRM MAXIMUM LIMITS. AT EACH AREA THE FOLLOWING WAS ACCOMPLISHED: ALODINED BLEND-OUTS. FABRICATED AND INSTALLED REPAIR STRAPS USING .050 INCH 301 1/2 HARD STAINLESS STEEL. PRIMED AND FILLED AREAS ACCOMPLISHED PER ENGINEERING INSTRUCTIONS PER MRB 767-1462. TST: 42,812.00 HOURS. CYCLES: 8,763. (X)