TUL - CORROSION ON UPPER SIDE OF STR 19R AT BS 475 BELOW COOLING AIR EXHAUST DUCT. REPAIRED STRINGER PER SRM 53-10-3. TST: 70,323.2 HOURS. CYCLES, 48,507. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - CORROSION ON UPPER SIDE OF STR 19R AT BS 475 BELOW COOLING AIR EXHAUST DUCT. REPAIRED STRINGER PER SRM 53-10-3. TST: 70,323.2 HOURS. CYCLES, 48,507. (X)