What was found
TUL - STA 380 FLOOR BEAM HAS CORROSION BETWEEN RT INBD TIE-DOWN TRACK AND RT CREASE ANGLE. REMOVED CORRODED PIECE OF FLOOR BEAM PER SRM 53-10-8. REPLACED WITH FLOOR BEAM REPAIR IAW SRM 53-10-8. TST: 55,509 HOURS. CYCLES, 33,962. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - STA 380 FLOOR BEAM HAS CORROSION BETWEEN RT INBD TIE-DOWN TRACK AND RT CREASE ANGLE. REMOVED CORRODED PIECE OF FLOOR BEAM PER SRM 53-10-8. REPLACED WITH FLOOR BEAM REPAIR IAW SRM 53-10-8. TST: 55,509 HOURS. CYCLES, 33,962. (X)