What was found
TUL - OUTER FLOOR BOARD ATTACHMENT FLANGE AREAS HAVE CORROSION DAMAGE RT SIDE AT LAVATORY. INSTALLED NEW SECTION OF FLOOR SUPPORT PER AARD 51-10-00-3, AND SPLICED IN IAW SRM 53-10-16-2, FIG 204. TST: 26,111. CYCLES: 10,811. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - OUTER FLOOR BOARD ATTACHMENT FLANGE AREAS HAVE CORROSION DAMAGE RT SIDE AT LAVATORY. INSTALLED NEW SECTION OF FLOOR SUPPORT PER AARD 51-10-00-3, AND SPLICED IN IAW SRM 53-10-16-2, FIG 204. TST: 26,111. CYCLES: 10,811. (X)