TUL - CORROSION ON RIGHT UPPER TRAILING EDGE FROM TIP TO 48 INCHES INBOARD, INBOARD OF PCU, 86 INCHES FROM OUTBOARD END, 70 INCHES FROM OUTBOARD END. REMOVED OLD BEAM AND REPLACED WITH SERVICEABLE BEAM IAW SRM 51-10-1 PAGE 4. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - CORROSION ON RIGHT UPPER TRAILING EDGE FROM TIP TO 48 INCHES INBOARD, INBOARD OF PCU, 86 INCHES FROM OUTBOARD END, 70 INCHES FROM OUTBOARD END. REMOVED OLD BEAM AND REPLACED WITH SERVICEABLE BEAM IAW SRM 51-10-1 PAGE 4. (M)