What was found
LEFT GENERATOR DRIVE LIGHT DID NOT EXTINGUISH DURING ENGINE START. ACCOMPANIED BY EICAS MSG. LEFT ENG IDG BPCU BITE CARRIED OUT SHOWS LOW OIL PRESS ON LEFT IDG NL SPARES AT GLA ITEM DEFERRED RIGHT IDG AND APU OIL SERVICE CARRIED OUT. TEST OK ITEM TRANSFERRED TO MIC. REMOVED AND REPLACED LEFT IDG PER MM CHECK LEAK AND OPS CHECK GOOD. REMOVED MEL 10-259DC-13 MIC. (M)