SDR AALA972023

Service difficulty report · Sensing Line · Doug DC982

Difficulty date
October 27, 1997
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N59523
Make and model
Doug DC982
Aircraft serial
49915
Engine
Pwa JT8D217A
Part
Sensing Line
Part number
79137451257
Condition
Cracked
Location
Right
Stage of operation
CL
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLT 751 - AFTER TAKEOFF FLL DURING CLIMB-OUT, AFT COMPT OVERHEAT LIGHT ILLUMINATED. ACCOMPLISHED ABNORMAL PROCEDURES AND LIGHT EXTINGUISHED WHEN POWER LEVERS RETARDED. AIRCRAFT RETURNED TO FLL AND LANDED OVERWEIGHT WITHOUT INCIDENT. PLACARDED RIGHT AUGMENTATION VALVE AND CAPPED DOWNSTREAM PRESSURE SENSING LINE. ACCOMPLISHED OVERWEIGHT LANDING INSPECTION WITH NO DEFECTS FOUND. SUBSEQUENTLY REPLACED RT AUGMENTATION VALVE DOWNSTREAM PRESSURE SENSIONG LINE AND REMOVED PLACARD AT DFW. SYSTEM LEAK AND GROUND CHECKED NORMAL OPERATION. (M)