SDR AALA972047

Service difficulty report · Actuator · Fokker F28MK0100

Difficulty date
October 28, 1997
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N1452B
Make and model
Fokker F28MK0100
Aircraft serial
11464
Part
Actuator
Part number
9409122
Condition
Defective
Location
Fuel System
Stage of operation
CL
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

LGA - FLT 253 - AFTER TAKEOFF LGA DURING CLIMB-OUT, FUEL CROSSFEED C/B POPPED. FUEL QUANTITY DECREASED MORE RAPIDLY IN RT WING TANK THAN LEFT WING TANK AND FUEL CROSSFEED FLOW BAR WOULD NOT ILLUMINATE. AIRCRAFT RETURNED TO LGA AND LANDED WITHOUT INCIDENT. REPLACED BOTH FUEL CROSSFEED VALVE ACTUATORS. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

More about the Fokker F.28 MK 0100