What was found
AFW - FLOORBEAM HAS CORROSION BEYOND SRM LIMITS AFTER BLENDING. FABRICATE .050 STRAP FROM 301 STAINLESS AND INSTALL WET WITH BMS 5095 PER ENGINEERING MRB 767-1476. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFW - FLOORBEAM HAS CORROSION BEYOND SRM LIMITS AFTER BLENDING. FABRICATE .050 STRAP FROM 301 STAINLESS AND INSTALL WET WITH BMS 5095 PER ENGINEERING MRB 767-1476. (M)