What was found
AFW - FOUND AND BLENDED OUT AN AREA OF CORROSION ON THE LOWER SURFACE OF THE FRAME INNER CHORD FORWARD FLANGE IN THE AFT CARGO COMPARTMENT. THE BLEND-OUT EXCEEDS SRM MAXIMUM LIMITS. REFINISHED BLENDED AREA PER SRM 53-00-07. APPROVED FOR CONTINUED SERVICE WITH NOTED CONDITION BY ENGINEERING PER MRB 767-1479. TST: 27,633.03 HOURS. CYCLES: 4,256. (X)