AFW - FLOOR BEAM CORRODED BEYOND SRM LIMITS AFTER BLEND-OUT. INSTALLED 0.050 INCH REPAIR STRAP PER ENGINEERING MRB 767-1528. TST: 27,657.11 HOURS. CYCLES: 4,334. (X)