As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
TUL - FLOORBEAM UPPER CHORD CORRODED FROM LBL 10 TO LBL 14. REMOVED CORROSION PER SRM 51-10-06. CUT AND REMOVED DAMAGED SECTION OF FLOORBEAM. ALODINED AND PRIMED, INSTALLED DOUBLER PER SRM 53-10-8. FIGURES 1-4. TST: 56,187 HOURS. CYCLES: 34,681. (X)