What was found
TUL - PREVIOUS REPAIR CORRODING ON TOP OF FLOORBEAM AT STATION 400 RBL 10 TO 14 INCH. REMOVED DAMAGED AREA AND REPAIRED PER SRM 53-10-8. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - PREVIOUS REPAIR CORRODING ON TOP OF FLOORBEAM AT STATION 400 RBL 10 TO 14 INCH. REMOVED DAMAGED AREA AND REPAIRED PER SRM 53-10-8. (M)