What was found
MIA - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH ARROWS AT R4 DOOR INOPERATIVE. REPLACED EMERGENCY EXIT FLOOR PATH ARROW LIGHT STRIP AT R4 DOOR. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MIA - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH ARROWS AT R4 DOOR INOPERATIVE. REPLACED EMERGENCY EXIT FLOOR PATH ARROW LIGHT STRIP AT R4 DOOR. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)