What was found
TUL - FOUND CORROSION ON FLOORBEAM 60 AT NR 5 TRAY. SPLICED IN NEW FLOORBEAM SECTION AS PER SRM 53-10-15-2, TREATED, PRIMED AND PAINTED EPR SRM 51-21-00. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND CORROSION ON FLOORBEAM 60 AT NR 5 TRAY. SPLICED IN NEW FLOORBEAM SECTION AS PER SRM 53-10-15-2, TREATED, PRIMED AND PAINTED EPR SRM 51-21-00. (M)